← Waterloo Concourse Display

Engineering summary

STEP 4 OF 6 · CFG-2041 · CONCOURSE MAIN SCREEN
{{ approveLabel }}
RULE VERSIONDISPLAY-CALC v1.3.0
CALCULATED14 Jul 2026 · 14:02
PRODUCTVIVID 1.25 COB · A10s Pro
INPUT SNAPSHOT4800 × 1013 mm · qty 1 · 5% spares · 230 V / 16 A
Display
Cabinet grid8 × 3 · 24 cabinets Actual size4,800 × 1,012.5 mm Active area4.86 m² Resolution3,840 × 810 px · 3.11 MP Aspect ratio4.7407 Total weight163.2 kg Spare cabinets2 (5%, rounded up)
Power & thermal
Max power4,080 W Average power1,560 W Heat output13,922 BTU/h Circuit capacity @ 80%2,944 W / circuit Estimated circuits2 × 16 A @ 230 V Distribution12 cabinets / circuit
Data path
Total pixels3,110,400 Max pixels / port650,000 Data ports required5 primary + 5 backup † Receiving cards24 × NovaStar A10s Pro ControllerNovaStar VX1000 · 10 ports Port headroom0 of 10 free with backup
Warnings & overrides
W-01 Backup data consumes all VX1000 ports — no expansion headroom. Consider VX1000 Pro if a second display is added.
† OVR
Data ports raised 5 → 5+5 (full backup path). REASON: CLIENT REDUNDANCY REQUIREMENT · R. CHEN · 10 JUL
Every override is recorded against the calculation snapshot.
← Back to cabinets Continue to quote →